• New
  • Out-of-Stock
New Out-of-Stock

1500VA/900W 12VDC Inverter Charger

$150,000
Qty
Out-of-Stock

SKU: INVCAR900

  • Automatic transfer from line to battery
  • Rack/tower design, installation versatility
  • Wider adjustable input voltage range and charging current
  • Intelligent charging control, efficient charging
  • Automatic restart when main power is restored
  • Superior protection: low battery, overcharge, overload, over temperature and short circuit
  • High load capacity, supporting various household loads and IT equipment (<50% half-wave load, <30% inductive load)
Topology
Power VA/Watts 1500/900w
Output Power Factor 0.6
Format Tower
Panel LCD + LED
ENTRANCE
Nominal voltage 220 / 230 / 240 Vac (selectable)
Voltage Range 220 / 230 / 240 Vac, -22% / -59% ~ +26%,
± 5 Vac (selectable)
Frequency 50/60 Hz (auto-sensing)
Frequency Range ±10% (default), ±5% ~ 15% (selectable)
EXIT
Power Factor 0.6
Output Voltage Battery mode: 220 / 230 / 240 Vac±10% (selectable)
Mains mode: synchronized with utility power
Output Frequency Battery mode: 50 / 60 Hz±1% (selectable);
Mains mode: synchronized with utility power
Waveform Battery mode: square wave; Mains mode: synchronized with utility power
Inverter efficiency ≥ 83% (max.)
IT equipment Forks
Half-wave load ≤ 50% (rated load)
Inductive load ≤ 30% (rated load)
BATTERY
Rated voltage 12 VDC
Max charging current B20 / 10 A ± 3 A (selectable)
Voltage charge equalization Single battery 14.2 ± 0.3 Vdc (default), 13.6 ~ 15.0 Vdc (selectable)
Floating Voltage Single battery 13.6 ± 0.3 Vdc
Low voltage alarm Single battery 10.8 ± 0.3 Vdc (default), 9.6 ~ 13.0 Vdc (selectable)
Low voltage shutdown Single battery 10.2 ± 0.3 Vdc (default), 9.6 ~ 12.0 Vdc (selectable)
Overvoltage protection Single battery 15.0 ± 0.3 Vdc
Overvoltage recovery Single battery 13.6 ± 0.3 Vdc
SYSTEM
Transfer Time ≤ 8 ms (typical), ≤ 15 ms (max.)12 VDC
Protection Overload, short circuit, over-temperature, output over/under-voltage, excessive low battery
Overload times (Mains mode) ≥ 110% for 120 s, ≥ 125% for 60 s, ≥ 150% for 10 s, ≥ 200% for 1 s
Overload times (Battery mode) ≥ 110% for 60 s, ≥ 125% for 5 s, ≥ 150% for 1 s
communication interface No
Low voltage shutdown Single battery 10.2 ± 0.3 Vdc (default), 9.6 ~ 12.0 Vdc (selectable)
Overvoltage protection Single battery 15.0 ± 0.3 Vdc
Overvoltage recovery Single battery 13.6 ± 0.3 Vdc
 OTHERS
Operating Temperature 0 ~ 45℃
Operation Humidity 0 ~ 95% (non-condensing)
Altitude ≤ 1000 m (Above 1000 m, derating 1% for each additional 100 m)
IP Protection IP 20
Cooling Forced-air cooling
Noise < 45 dB
Dimensions (W x D x H) (mm) 245 x 220 x 80
Packaging Dimension (W x D x H) (mm) 315 x 290 x 156
Net Weight 2.68

Contact us via WhatsApp